Välj region
Bekräfta

Flow-c Anesthesia Machine

Our compact anesthesia model

Flow-c is the easy-to-use dynamic anesthesia machine. Despite its small size, it offers all Flow Family innovations, making sure to cover the need of care efficiency.

That in combination with its compact design gives it an advantage in the crowded Operating Room in a hospital as well as Ambulatory Surgery Centers, all with a busy schedule.

Dynamic Anesthesia Delivery when Every. Breath. Counts. 

 

Getinge Flow-c is our compact, easy-to-use anesthesia machine for the busy OR
Getinge’s compact anesthesia machine Flow-c has 215 cm multipurpose rails for mount monitors, tables and accessories.
Our compact anesthesia machine, Getinge Flow-c , offers cable management without clutter designed for the crowded OR

Compact efficiency in the busy OR

Flow-c is our compact anesthesia machine enabling safe and cost-efficient treatment.

  • Ventilation performance to ICU standards
  • Safe low-flow anesthesia with Automatic Gas Control
  • MAC Brain for improved control of depth of anesthesia
  • Active hypoxia prevention with O2Guard
  • Lung Recruitment Maneuvers to prevent postoperative complications

Our unique anesthesia technology makes the difference

 

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. With simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1][2][3][4][5][6]

 

Better anesthetic agent dosing

For more precise control of depth of anesthesia, we created MAC Brain. A unique tool that visualizes the difference in agent concentration between the lungs and the target organ, the brain. The reliability of the data puts you in control, letting you plan and deliver more efficient dosing of agents with safety and ease. [8][9][10]

User-friendly workstation in the OR

 

Large drawer

With slots for spare vaporizers and an optional lockable compartment.

 

Cable management

Hoses and cables are neatly routed and covered by specially designed panels, contributing to improved hygiene and safety.

 

215 cm rails for flexible mounting

Despite its compact size, Flow-c has 215 cm multipurpose rails! Mount monitors, tables and accessories where it best suits you.

Ansvarsfriskrivning

Produkterna, tillgängligheten för anestesisystemen i Flow-serien och programversionen kan vänta på regulatoriska godkännanden för marknadsföring i ditt land. Vänligen kontakta din Getinge-representant för mer information. De uttalanden som lämnas av läkare är uteslutande läkarens och speglar inte nödvändigtvis Getinges uppfattning.
Juridisk tillverkare · Maquet Critical Care AB · Röntgenvägen 2 SE–171 54 Solna · Sverige · +46 (0)10 335 73 00

Our unique anesthesia technology makes the difference

AGC Anesthesia Flow

Automatic Gas Control (AGC)

Safe and easy low-flow anesthesia

Automatic Gas Control (AGC) makes low-flow anesthesia delivery safe. It is an option uniquely available with Flow-i machines. Automation eliminates the need of continuous manual adjustments: with simple pre-settings, specifying the targeted inspired oxygen, end-tidal anesthetic agent levels and required speed, AGC solves the rest. Our innovation offers high precision combined with improved comfort and increased safety. [1] [2] [3] [4] [5] [6]

o2guard anesthesia flow

O₂Guard

Active hypoxia prevention

Our O2Guard is the world’s only system for active hypoxia prevention. Should the inspired oxygen level drop below 21%, the O2Guard automatically overrules the settings and increases the flow of oxygen. [7]

Mac brain anesthesia flow

MAC Brain

Better anesthetic agent dosing

For more precise control of depth of anesthesia, we created MAC Brain. A unique tool that visualizes the difference in agent concentration between the lungs and the target organ, the brain. [8] [9] [10]

Lung recruitment flow anesthesia

Lung recruitment

Gentle steps against atelectasis

Our lung recruitment maneuvers have become the tool of choice to counter
atelectasis, to improve oxygenation and help prevent postoperative complications. [11] [12]

Ventilation anesthesia flow

Ventilation performance

To ICU standards

Innovative Flow Core Technology is designed to promote efficient agent usage, providing the power and precision to ventilate even the most challenging patients. [13] [14] [15]

User-friendly workstation in the OR

Developed together with clinicians, the compact Flow-c anesthesia machine is designed to facilitate a great scope for configuration and patient safety. With an intuitive interface and emphasis on ease of use [16], our anesthesia solutions ensure a streamlined workflow and efficiency in the operating room that offers enhanced cost control and resource management.

Our anesthesia workstation

Our anesthesia workstation

Heltäckande service och support

 

Undvik att avbryta procedurer

Anslut och ta kontroll

Webbportalen Getinge Online ansluter dig till alla Getinge-enheter och ger dig tillgång till värdefulla data som hjälper biomedicinska analytiker och läkare i deras dagliga arbete. Portalen är ett kraftfullt verktyg för att förbättra drifttiden och effektivt använda sjukhusets resurser. 

  • Förbättra drifttiden i operationssalen
  • Minska kostnader och koldioxidavtryck
Man looking straight smiling

Ett enhetligt erbjudande

Getinges heltäckande tjänster maximerar drifttiden och det långsiktiga värdet av din investering. Vi tillhandahåller en serviceplan som innefattar proaktivt underhåll, enkel felsökning och snabb service av våra certifierade lokala representanter – så att din utrustning hela tiden fungerar optimalt.

Anesthesia consumables

Förbrukningsartiklar av hög kvalitet

Getinges sortiment av originalförbrukningsartiklar är särskilt utvecklat för högsta möjliga patientsäkerhet och användarvänlighet. Våra originaltillbehör och förbrukningsartiklar garanterar bästa prestanda och säkerhet för anestesitillförselsystemet inom Flow-serien.

MSync

Anslutningar mellan system

MSync gör det enkelt att ansluta Flow-maskinen till patientmonitorn, HIS och patientdatahanteringssystemet utan behov av ett tredjepartssystem. Patientdata överförs via HL7 (MSync) i realtid för att stödja beslutsfattande.

  • The Getinge Online web portal connects you to any Getinge device, getting access to valuable data that will support biomeds and clinicians in their daily work.

Visit our Academy – training and education designed to enhance your proficiency

For more information about our onsite events or remote trainings, you can also contact your local sales & service representative.

  1. 1. Carette R, De Wolf AM, Hendrickx JF. Automated gas control with the Maquet Flow-i. J Clin Monit Comput. 2016 Jun;30(3):341-6.

  2. 2. Getinge case story MX-7418, rev01: Agent savings with Flow-i AGC at Maria Middelare hospital, Belgium.

  3. 3. Lucangelo U, Garufi G, Marras E, et al. End-tidal versus manually-controlled low-flow anaesthesia. J Clin Monit Comput. 2014; 28: 117-121.

  4. 4. Brattwall M, Warrén-Stomberg M, Hesselvik F, Jakobsson J. Brief review: Theory and practice of minimal fresh gas flow anesthesia. Can J Anaesth. 2012 Aug;59(8):785-97

  5. 5. M. Bilgi, S. Goksu, A. Mizrak, et al. Comparison of the effects of low-flow and high-flow inhalational anaesthesia with nitrous oxide and desflurane on mucociliary activity and pulmonary function tests, Eur J Anaesthesiol 2011;28:279–283

  6. 6. Kalmar A. et al. Minimizing sevoflurane wastage by sensible use of automated gas control technology in the flow-i workstation: an economic and ecological assessment. J Clin Monit Comput. 2022 Jan 3. doi: 10.1007/s10877-021-00803-z.

  7. 7. Ghijselings IE, De Cooman S, Carette R, et al. Performance of an active inspired hypoxic guard. J Clin Monit Comput. 2016 Feb;30(1):63-8t.

  8. 8. Drews FA, Syroid N, Agutter J, Strayer DL, Westenskow DR. Drug delivery as control task: improving performance in common anesthetic task. Hum Factors 2006;48:85–94.

  9. 9. ECRI. The MAC Brain feature on Getinge anesthesia units: ECRI's view. Device Evaluation 2022 Jan5.

  10. 10. Internal report EVU-197031 - 01 - Flow 4.7 Enhanced Post Market Surveillance Report 2019

  11. 11. García-Fernández J, Romero A, Blanco A, et al. Recruitment manoeuvres in anaesthesia: How many more excuses are there not to use them? Rev Esp Anestesiol Reanim.2018 Apr;65(4):209-217

  12. 12. Yassen et al. Respiratory and Hemodynamic Effects of Prophylactic Alveolar Recruitment During Liver Transplant. Experimental and Clinical Transplantation (2021) DOı: 10.6002/ect.2020.0412

  13. 13. Internal test reports comparing Flow-i with vendor machines; EVU 125310, EVU-125312, EVU-125313

  14. 14. Case study contributed by Dr. Waltraud Bruchelt and Dr. Günter Baumann, Dept. of Anaesthesiology and Intensive Care Medicine, University Hospital Graz, Austria.

  15. 15. Lucangelo U, Ajčević M, Accardo A, et al. Flow-i ventilator performance in the presence of a circle system leak. J Clin Monit Comput. 2017 Apr;31(2):273 280.

  16. 16. Internal report EVU 205592 NPS Summary Anesthesia 2019